error: Content is protected !!
>

Addressable Fire Alarm System

SIEMENS Cerberus Pro UL (FC901 1Loop Panel)

ARCHITECT AND ENGINEER SPECIFICATIONS

Fire alarm control panel (FACP) for up to 50 addressable points that is comprised of the following three (3) system components:
  • Main board (Model FCM901-U3)
  • 6.5 Amps (170-Watt power supply (Model FP2011-U1)
  • System enclosure (Model FH901-U3 / R3)
System features:
  • Supports 50 addressable devices on one (1) `Class A’, or two (2) `Class B’ circuits
  • Includes one (1) `Class A’, or two (2) `Class B’ notification appliance circuits (NACs)
  • Built-in digital alarm communication transmitter (DACT)
  • Supports Carbon Monoxide (CO) detection
  • Downloads, prints system-event history & detector sensitivity
  • Supervised remote printer (Model FCA2018-U1)
  • Optional connectivity to a leased-line / city-tie module (Model FCI2020-U1)
  • Built-in RS─485 connection for remote annunciators
  • Resettable and non-resettable 24VDC auxiliary power
  • Off-normal warning message prior to reset
  • Fast and easy set-up with custom-configuration tool
  • Supports a 182-character display

SIEMENS Cerberus Pro UL (FC922-924 2-4Loop Panel)

ARCHITECT AND ENGINEER SPECIFICATIONS

Comprised of the following system components:
  • Operating units
  • Periphery boards
  • Power supplies
  • System enclosures
System features:
  • Supports 252-to-504 addressable devices:
    • One (1) to four (4) ‘Class B’; one (1) to two (2) ‘Class A’ for Model FC922
    • One (1) to eight (8) ‘Class B’; one (1) to four (4) ‘Class A’ for Model FC924
  • Includes one (1) ‘Class A’ or two (2) ‘Class B’ notification appliance circuits (NACs)
  • Resettable and non-resettable 24VDC, [nominal] auxiliary power
  • Connectivity to a leased-line / city-tie module
  • Releasing module supports activation of releasing valves in pre-action / deluge systems / agent release
  • Off-normal warning message prior to reset
  • Fast and easy set-up with auto-configuration feature
  • Cerberus® DMS Danger Management Station can monitor and control up to 32 Models FC922 and FC924 FACPs
  • Digital alarm communication transmitter (DACT)

SIEMENS Cerberus Pro EN (2-12 Loop Panel)

Protecting people and assets. Securing business processes and continuity. This is what fire protection is all about. Cerberus® PRO is a powerful fire protection system for fast, reliable fire detection, alarm signaling, and control. Its wide portfolio of innovative products provides clever technology with extensive safety features for small to very large applications. So you can be sure to meet your application with confidence.

SIEMENS XLS Fire Finder - (1-12 Loop)

Greater flexibility and compatibility.

For the greatest possible protection, the FireFinder system operates with a full range of proven, high-performance devices and systems, including:

  • Network Command and Control (NCC) and Wide Area Network Systems (NCCWAN)
  • Multiple FireFinder Networking System (compatible with MXL)
  • Integrated digital emergency voice evacuation system
  • FirePrint intelligent fire detectors
  • Special hazards extinguishing systems
  • Notification devices

Xtralis - VESDA System

Our Clients

If You Need Any Solution ... We Are Available For You

Contact Us